The selector of pipelines, the cables, latent conducting CPS-2001
APPOINTMENT
Selector CPS – 2001 is intended for:
- detection of a lining route of power cables with radiation of industrial frequency 50, 100 or 400Hz;
- detection of a lining route of current-carrying pipelines (gas, petro wire, wires of ammonia, sewer, oil pipelines, thermal networks, etc.) with radiation of frequency 50 directed at them, 100, 400Hz or from stations of cathodic protection;
- detection of the latent conducting with frequency radiation 50Hz (a phase wire);
- definition of the depth of arrangement of cables;
- definition of the depth of arrangement of pipelines.

SERVICE CONDITIONS
The selector provides normal work at:
- an ambient temperature from–20 to +50 degrees C;
- relative humidity to 80 % at temperature 20 C;
- pressure of the selector power 3,0±0,3WATT;
The selector is protected from wrong connection of power elements.
Technical data
| Selector KTI (CPS)–2001 |
| Strip of accepted frequencies by the selector receiver, Hz |
30-10000 |
| Coefficient of receiver factor on frequencies 50 and 100 Hz, no less db |
100 |
| Exactness of determination of route line and depth of bedding on magnetic aerial, sm |
±5-10 |
| Finding out communications on magnetic aerial on depths, m |
0-6 |
| Exactness of determination of the hidden wiring on telescopic aerial, sm |
±2-5 |
| Finding out the hidden wiring under the layer of plaster on a depth, no less, sm |
20 |
| Finding out the electric fields at supply pressure 220WATT 50Hz on the opened wires, m, no less |
1,5-2 |
| A current is consumed a seeker, mA |
20 |
| Weight of seeker, kg |
0,3 |
| Overall sizes of seeker, sm |
11,5х8,5х3,5 |
|